OPENu/sasquachianowns 3OPERATOR· 16d

The Power Cord Is VERY Hot!

I received my Bitfortun BS-4 yesterday and installed it using Red Panda's video as a guide. So far, the miner itself is great—it's quiet, small, and updating to the Harlo Labs firmware was a breeze. However, there are a couple of serious hardware issues right out of the box: 1: The stock power supply is dangerously underpowered. The included PSU is 350W, but the BS-4 pulls about 330W. Following the standard 80% rule for 24/7 continuous mining, the safe limit for a 350W PSU is only 280W. Pulling 330W means this unit is running at 94% capacity, completely ignoring the safety buffer. Running a PSU this hard around the clock causes extreme thermal stress, shortens its lifespan, and severely increases the risk of component failure. My solution: I replaced it entirely with a 600W power supply (Mean Well LRS-600-12 12V/50A) from Amazon for $69. 2: The DC power cord gets dangerously hot. The power cord running to the miner is very hot to the touch, regardless of which power supply is used. There are two reasons for this: The wire gauge is too thin. Drawing over 300 watts at 12 volts pulls a massive 25 Amps of continuous current. To handle that safely without overheating, the DC wires need to be 10 or 12 AWG. The included wires are too thin, causing the copper to act like a resistor and generate heat. No terminal connectors. The wires are just stripped bare and pushed directly under the screw terminals. For high-current mining, it is highly recommended to crimp fork or ring terminals onto the wires first to ensure maximum surface contact and prevent heat buildup. My solution: Since the BS-4 uses an XT60 connector, I have two choices to fix this. I can either build a replacement cord using 10/12 AWG wire and an XT60 adapter, or I can use the three +V and -V terminals on the power supply to run multiple wire pairs to the miner, splitting the current to keep the wires cooler. Just my two cents. I am honestly surprised I have to make safety modifications to brand-new equipment just to run it properly. I have two 40T Magic Miners shipping next week, and I'm really hoping I don't find similar issues with those out of the box. Will Harlo Labs be correcting any of this any time soon?

0
u/jon-heliumdeployHELIUM DEPLOY· answered 16d after the question

Replace the cord with 10 or 12 AWG wire and proper crimped terminals—you're right that the stock wire is undersized for 25 amps continuous, and that's why it's heating up. Running multiple pairs from the supply terminals works too if you want to split the load. The 600W Mean Well you bought is the right move; the stock 350W brick is at the edge and will cook itself over time. The Magic Miners ship with a beefier external supply and don't run into this. If the cord gets too hot to hold for more than a few seconds or you see discoloration on the terminals, stop and email support@heliumdeploy.com with a photo. Common mistake: trusting the stock wire gauge on budget miners that push 300+ watts—always check the current draw in amps and match the wire to it.

1
u/k3bazowns 4CAPTAIN· 16d

I agree you your assmeny, keep the 600w power supply, teminate both the input and output (if not already) and get a larger guage wire between the power supply and the miner. In a perfect world it would come that way from the manufacter, but here we are.

Log in to jump in. Confirmed fixes count toward your rank.

More on this